Glass enterprises admittance regulation of environmental protection
by:Lisson
2020-11-11
Daily-use glass industry should conform to the requirements of the clean production, improving design, using low sulfur content of fuel quality, control the use of sulfate and nitrate raw materials, banning the use of arsenic trioxide, antimony trioxide, lead, fluoride, chromium slag and other harmful raw and auxiliary materials, products after processing process should use environmental protection paint and preparation;
The use of advanced technology and equipment, improve management, comprehensive utilization and other measures, from the source to reduce pollution, improve the utilization efficiency of resources.
New or renewal project must achieve the daily glass industry evaluation index system of cleaner production in the cleaner production level of advanced enterprises.
1. New or renewal project cleaner production index of pollutants should reach the main pollutant of the newly built or renovated daily glass production projects control indicators in the quota target ( See table 7) 。
2. To carry out the cleaner production audit, to control the whole production process, to encourage enterprises to actively by GB/T24001 environmental management system certification.
( 2) End-treatment
1. Main pollutants did not reach the local discharge standards and total amount control indexes of newly built or renovated production project, must take the flue gas desulfurization dust removal of the main pollutants, end of the discharge of waste water treatment and management measures. Wastewater in principle should dispose of or access to the concentration of industrial wastewater treatment facilities after treatment standards, shall not be connected to the urban sewage treatment system. Is really necessary, the access to the town sewage treatment system must be reported to the competent department of urban sewage treatment industry fully demonstrated, for the urban drainage license rear can access. Access to the urban sewage treatment system of household glass production enterprise, the discharge of waste water pollutants index should achieve centralized sewage treatment plant or 'sewage discharged into urban sewage water quality standard' regulation requirements.
2. Producer gas as the main fuel of the newly built or renovated glass furnace, must be set in flue dust removal or contain dust control device, at the end of to ensure the furnace during commutation, flue gas emissions of air pollutants emission standards of industrial furnaces ( GB9078) Regulations limit requirements.
3. The newly built or renovated glass furnace, flue gas denitration treatment facilities should be reserved.
( 3) Pollutant on-line monitoring
sewage discharge and furnace flue gas discharge shall, in accordance with requirements of the environmental protection department, set up the online monitoring system.
( 4) To control the pollutant emission, pollutant emissions to comply with national and local pollutant emission ( Control) Standard, the total discharge of major pollutants conform to the requirements of the total amount control.
( 5) Construction and reconstruction projects must be strictly implemented the law of the People's Republic of China on environmental impact assessment law ', in accordance with the law to have approval of the examination and approval of the competent administrative department for environmental protection of the environmental impact assessment documents. According to the environmental protection & other; Three at the same time & throughout; Construction and project matching requirements of environmental protection facilities and apply for project completion acceptance of environmental protection.
1. New or renewal project cleaner production index of pollutants should reach the main pollutant of the newly built or renovated daily glass production projects control indicators in the quota target ( See table 7) 。
2. To carry out the cleaner production audit, to control the whole production process, to encourage enterprises to actively by GB/T24001 environmental management system certification.
( 2) End-treatment
1. Main pollutants did not reach the local discharge standards and total amount control indexes of newly built or renovated production project, must take the flue gas desulfurization dust removal of the main pollutants, end of the discharge of waste water treatment and management measures. Wastewater in principle should dispose of or access to the concentration of industrial wastewater treatment facilities after treatment standards, shall not be connected to the urban sewage treatment system. Is really necessary, the access to the town sewage treatment system must be reported to the competent department of urban sewage treatment industry fully demonstrated, for the urban drainage license rear can access. Access to the urban sewage treatment system of household glass production enterprise, the discharge of waste water pollutants index should achieve centralized sewage treatment plant or 'sewage discharged into urban sewage water quality standard' regulation requirements.
2. Producer gas as the main fuel of the newly built or renovated glass furnace, must be set in flue dust removal or contain dust control device, at the end of to ensure the furnace during commutation, flue gas emissions of air pollutants emission standards of industrial furnaces ( GB9078) Regulations limit requirements.
3. The newly built or renovated glass furnace, flue gas denitration treatment facilities should be reserved.
( 3) Pollutant on-line monitoring
sewage discharge and furnace flue gas discharge shall, in accordance with requirements of the environmental protection department, set up the online monitoring system.
( 4) To control the pollutant emission, pollutant emissions to comply with national and local pollutant emission ( Control) Standard, the total discharge of major pollutants conform to the requirements of the total amount control.
( 5) Construction and reconstruction projects must be strictly implemented the law of the People's Republic of China on environmental impact assessment law ', in accordance with the law to have approval of the examination and approval of the competent administrative department for environmental protection of the environmental impact assessment documents. According to the environmental protection & other; Three at the same time & throughout; Construction and project matching requirements of environmental protection facilities and apply for project completion acceptance of environmental protection.